Power Standards Lab PQP-ETH1-00 related products

Power Standards Lab PQP-ETH1-00
Stock photo
Power Standards Lab ATT1-0600V-00
Power Standards Lab / ATT1-0600V-00 
Voltage Attenuator module. ±600VDC, CAT IV 300Vac. For connection to PQube AN1-AN2 channels.
Power Standards Lab ATT1-1200V-00
Power Standards Lab / ATT1-1200V-00 
Voltage Attenuator module. ±1200VDC, CAT IV 600Vac. For connection to PQube AN1-AN2 channels.
Power Standards Lab ATT2-0600V-00
Power Standards Lab / ATT2-0600V-00 
Voltage and Current Module. ±600VDC, (CAT IV 300Vac) input, and ±10V current input. For connection to PQube AN1-AN2 channels. Great for high voltage DC power monitoring. Must be ordered with Hall Effect Sensor
Power Standards Lab BAT-LP-0.6AH-00
Power Standards Lab / BAT-LP-0.6AH-00 
PQube Replacement Battery with custom pull tab. Lithium Polymer. 0.6 Amp-Hour.
Power Standards Lab CB-1P-277-480V-1A
Power Standards Lab / CB-1P-277-480V-1A 
Single-Phase Circuit breaker for use with PQube. 277/480 volt, 1 amp, DIN rail mount.
Power Standards Lab CB-3P-277-480V-1A
Power Standards Lab / CB-3P-277-480V-1A 
3-Phase Circuit breaker for use with PQube. 277/480 volt, 1 amp, DIN rail mount.
Power Standards Lab CSDC-R-CL-0050A-4V
Power Standards Lab / CSDC-R-CL-0050A-4V 
Hall effect DC Current Sensor, Solid-core, Closed Loop, Rectangular, 0.81" x 0.41" opening, 50A
Power Standards Lab CSDC-R-CL-0100A-4V
Power Standards Lab / CSDC-R-CL-0100A-4V 
Hall effect DC Current Sensor, Solid-core, Closed Loop, Rectangular, 0.81" x 0.41" opening,100A
Power Standards Lab CSDC-R-CL-0200A-4V
Power Standards Lab / CSDC-R-CL-0200A-4V 
Hall effect DC Current Sensor, Solid-core, Closed Loop, Rectangular, 0.81" x 0.41" opening, 200A
Power Standards Lab CSDC-R-CL-0400A-4V
Power Standards Lab / CSDC-R-CL-0400A-4V 
Hall effect DC Current Sensor, Solid-core, Closed Loop, Rectangular, 2.0" x 0.51" opening, 400A
Power Standards Lab CSDC-R-CL-0600A-4V
Power Standards Lab / CSDC-R-CL-0600A-4V 
Hall effect DC Current Sensor, Solid-core, Closed Loop, Rectangular, 2.0" x 0.51" opening, 600A
Power Standards Lab CT4-20A-00
Power Standards Lab / CT4-20A-00 
CT4 Current Sense Module. Nominal 20 amps (±70 amps instantaneous).
Power Standards Lab CTE1-10T-0.333V-00
Power Standards Lab / CTE1-10T-0.333V-00 
Combined Ethernet and Current Transformer Interface Module - 0.333 volt RMS (±1.2 volts instantaneous). Includes earth current monitoring with PQube-02 and later models. Not UL/TUV recognized.
Power Standards Lab CTE1-10T-1V-00
Power Standards Lab / CTE1-10T-1V-00 
Combined Ethernet and Current Transformer Interface Module - 1 volt RMS (±3.5 volts instantaneous). Includes earth current monitoring with PQube-02 and later models. Not UL/TUV recognized.
Power Standards Lab DRK-270-00
Power Standards Lab / DRK-270-00 
Din Rail Kit - 270mm long DIN rail with 2 end stops
Power Standards Lab ENCL-EXT1074-01
Power Standards Lab / ENCL-EXT1074-01 
Enclosure for PQube assembly. IP65 rated. 254mm x 181mm x 109mm deep (10" x 7.2" x 4.3" deep).
Power Standards Lab ETH1-10T-00
Power Standards Lab / ETH1-10T-00 
ETH1 Ethernet Module - Automatic e-mail, SNTP, POP, SMTP, FTP, HTTP, Modbus.
Power Standards Lab PQ1-01-0001
Power Standards Lab / PQ1-01-0001 
PSL - Power quality sensor, voltage dips, swells, interruptions; high-frequency impulses, 500 nanosecond response time; 3 relay contact outputs
Power Standards Lab PS1-100-240-00
Power Standards Lab / PS1-100-240-00 
PS1 Power Supply Module - Power PQube from 100V~240V, 50/60 Hz
Power Standards Lab PS2-100-240-00
Power Standards Lab / PS2-100-240-00 
PS2 Power Supply Module - Power PQube from 100V~240V, 50/60 Hz. Auxiliary output terminals - 24Vdc-200mA. Not UL/TUV recognized.
Power Standards Lab SC4L-1000A-333mV-2.5x2.5
Power Standards Lab / SC4L-1000A-333mV-2.5x2.5 
High accuracy split-core current sensor, 1000A:0.333mV, 0.6% accuracy, 600V, 50-400Hz, phase displacement <0.5º, 2.5"x2.5" opening.
Power Standards Lab SC4L-1500A-333mV-2.5x5.5
Power Standards Lab / SC4L-1500A-333mV-2.5x5.5 
High accuracy split-core current sensor, 1500A:0.333mV, 0.6% accuracy, 600V, 50-400Hz, phase displacement <0.5º, 2.5"x5.5" opening.
Power Standards Lab SC4L-2000A-333mV-3.0x5.0
Power Standards Lab / SC4L-2000A-333mV-3.0x5.0 
PSL - High accuracy split-core current sensor, 2000A:0.333mV, 0.6% accuracy, 600V, 50-400Hz, phase displacement <0.5º, 3"x5" opening.
Power Standards Lab SC4L-2000A-333mV-4.0x4.0
Power Standards Lab / SC4L-2000A-333mV-4.0x4.0 
High accuracy split-core current sensor, 2000A:0.333mV, 0.6% accuracy, 600V, 50-400Hz, phase displacement <0.5º, 4"x4" opening.
Power Standards Lab SC4L-3000A-333mV-4.0x6.0
Power Standards Lab / SC4L-3000A-333mV-4.0x6.0 
High accuracy split-core current sensor, 3000A:0.333mV, 0.6% accuracy, 600V, 50-400Hz, phase displacement <0.5º, 4"x6" opening.
Power Standards Lab SC4L-4000A-333mV-4.0x6.0
Power Standards Lab / SC4L-4000A-333mV-4.0x6.0 
High accuracy split-core current sensor, 4000A:0.333mV, 0.6% accuracy, 600V, 50-400Hz, phase displacement <0.5º, 4"x6" opening.
Power Standards Lab SC4L-5000A-333mV-4.0x7.0
Power Standards Lab / SC4L-5000A-333mV-4.0x7.0 
High accuracy split-core current sensor, 5000A:0.333mV, 0.6% accuracy, 600V, 50-400Hz, phase displacement <0.5º, 4"x7" opening.
Power Standards Lab SC4L-6000A-333mV-5.0x7.0
Power Standards Lab / SC4L-6000A-333mV-5.0x7.0 
High accuracy split-core current sensor, 6000A:0.333mV, 0.6% accuracy, 600V, 50-400Hz, phase displacement <0.5º, 5"x7" opening.
Power Standards Lab SC4L-800A-333mV-2.0x3.0
Power Standards Lab / SC4L-800A-333mV-2.0x3.0 
High accuracy split-core current sensor, 800A:0.333mV, 0.6% accuracy, 600V, 50-400Hz, phase displacement <0.5º, 2"x3" opening.
Power Standards Lab SCN2-1A-333mV-0.4
Power Standards Lab / SCN2-1A-333mV-0.4 
High accuracy split-core current sensor, hinge top, 1A:333mV. 0.2% accuracy, 600V, 40-600Hz, phase displacement <0.2º, 0.4"x0.4" opening.
Power Standards Lab SCN2-5A-333mV-0.4
Power Standards Lab / SCN2-5A-333mV-0.4 
High accuracy split-core current sensor, hinge top, 5A:333mV. 0.2% accuracy, 600V, 40-600Hz, phase displacement <0.2º, 0.4"x0.4" opening.
Power Standards Lab SCN3-100A-333mV-0.7
Power Standards Lab / SCN3-100A-333mV-0.7 
High accuracy split-core current sensor, hinge top, 100A:333mV. 0.2% accuracy, 600V, 40-600Hz, phase displacement <0.2º, 0.7"x0.7" opening.
Power Standards Lab SCN3-150A-333mV-0.7
Power Standards Lab / SCN3-150A-333mV-0.7 
High accuracy split-core current sensor, hinge top, 150A:333mV. 0.2% accuracy, 600V, 40-600Hz, phase displacement <0.2º, 0.7"x0.7" opening.
Power Standards Lab SCN3-20A-333mV-0.7
Power Standards Lab / SCN3-20A-333mV-0.7 
High accuracy split-core current sensor, hinge top, 20A:333mV. 0.2% accuracy, 600V, 40-600Hz, phase displacement <0.2º, 0.7"x0.7" opening.
Power Standards Lab SCN3-50A-333mV-0.7
Power Standards Lab / SCN3-50A-333mV-0.7 
High accuracy split-core current sensor, hinge top, 50A:333mV. 0.2% accuracy, 600V, 40-600Hz, phase displacement <0.2º, 0.7"x0.7" opening.
Power Standards Lab SCN4-200A-333mV-1.25
Power Standards Lab / SCN4-200A-333mV-1.25 
High accuracy split-core current sensor, hinge top, 200A:333mV. 0.2% accuracy, 600V, 40-600Hz, phase displacement <0.2º, 1.25"x1.25" opening.
Power Standards Lab SCN4-300A-333mV-1.25
Power Standards Lab / SCN4-300A-333mV-1.25 
High accuracy split-core current sensor, hinge top, 300A:333mV. 0.2% accuracy, 600V, 40-600Hz, phase displacement <0.2º, 1.25"x1.25" opening.
Power Standards Lab SCN4-400A-333mV-1.25
Power Standards Lab / SCN4-400A-333mV-1.25 
High accuracy split-core current sensor, hinge top, 400A:333mV. 0.2% accuracy, 600V, 40-600Hz, phase displacement <0.2º, 1.25"x1.25" opening.
Power Standards Lab SCN4-500A-333mV-1.25
Power Standards Lab / SCN4-500A-333mV-1.25 
High accuracy split-core current sensor, hinge top, 500A:333mV. 0.2% accuracy, 600V, 40-600Hz, phase displacement <0.2º, 1.25"x1.25" opening.
Power Standards Lab SCN4-600A-333mV-1.5x2.0
Power Standards Lab / SCN4-600A-333mV-1.5x2.0 
High accuracy split-core current sensor, hinge top, 600A:333mV. 0.2% accuracy, 600V, 40-600Hz, phase displacement <0.2º, 1.5"x1.2.0" opening.
Power Standards Lab SCSDC-O-0050A-4V
Power Standards Lab / SCSDC-O-0050A-4V 
Hall effect DC Current Sensor, Split-core, Open Loop, Round, 0.83" opening, 50A
Power Standards Lab SCSDC-O-0100A-4V
Power Standards Lab / SCSDC-O-0100A-4V 
Hall effect DC Current Sensor, Split-core, Open Loop, Round, 0.83" opening, 100A
Power Standards Lab SCSDC-O-0200A-4V
Power Standards Lab / SCSDC-O-0200A-4V 
Hall effect DC Current Sensor, Split-core, Open Loop, Round, 0.83" opening, 200A
Power Standards Lab SCSDC-O-0300A-4V
Power Standards Lab / SCSDC-O-0300A-4V 
Hall effect DC Current Sensor, Split-core, Open Loop, Round, 0.83" opening, 300A
Power Standards Lab SCSDC-O-0400A-4V
Power Standards Lab / SCSDC-O-0400A-4V 
Hall effect DC Current Sensor, Split-core, Open Loop, Round, 0.83" opening, 400A
Power Standards Lab SCSDC-R-0600A-4V
Power Standards Lab / SCSDC-R-0600A-4V 
Hall effect DC Current Sensor, Split-core, Open Loop, Rectangular, 2.5" x 0.63" opening, 600A
Power Standards Lab SCSDC-R-1000A-4V
Power Standards Lab / SCSDC-R-1000A-4V 
Hall effect DC Current Sensor, Split-core, Open Loop, Rectangular, 2.5" x 0.63" opening, 1000A
Power Standards Lab SD-4GB-01
Power Standards Lab / SD-4GB-01 
4 Gigabyte SanDisk brand SD card (note: one included with each PQube shipped)
Power Standards Lab TH1-80C-00
Power Standards Lab / TH1-80C-00 
TH1 Temperature-Humidity Probe
Power Standards Lab THC-2M-00
Power Standards Lab / THC-2M-00 
THC Extension Cable for Temperature-Humidity Probe - 2 meters long
Power Standards Lab XCT4-1A-00
Power Standards Lab / XCT4-1A-00 
XCT4 Current Transformer Interface Module - 1 amp RMS (±3.5 amps instantaneous).
Power Standards Lab XCT4-5A-00
Power Standards Lab / XCT4-5A-00 
XCT4 Current Transformer Interface Module - 5 amp RMS (±17 amps instantaneous).
Power Standards Lab XCT5-0.333V-00
Power Standards Lab / XCT5-0.333V-00 
XCT5 Current Transformer Interface Module - 0.333 volt RMS (±1.2 volts instantaneous). Includes earth current monitoring with PQube-02 and later models. Not UL/TUV recognized.
Power Standards Lab XCT5-1V-00
Power Standards Lab / XCT5-1V-00 
XCT5 Current Transformer Interface Module - 1 volt RMS (±3.5 volts instantaneous). Includes earth current monitoring with PQube-02 and later models. Not UL/TUV recognized.