Product specs for National Instruments Corporation 778572-46

National Instruments Corporation 778572-46

Product Description:

National Instruments Corporation 778572-46 NI PXI-2546 2.7 GHz 50 Ohm Dual 4X1 Multiplexer

  • 50 characteristic impedance
  • 2.7 GHz bandwidth
  • Insertion loss at 2.7 GHz <1.35 dB (typical <1.05 dB)
  • VSWR at 2.7 GHz <1.7 (typical <1.5)
  • Onboard relay counting
  • Use NI Switch Executive for calibrating losses on each channel of the PXI-2546
  • Configure Complete PXI System
  • Data Sheet
  • View Support Resources
The NI PXI-2546 is a dual 4x1 high-frequency multiplexer switch module suited for routing signals from DC to 2.7 GHz in 50 RF applications. It can switch up to 30 Vrms or 500 mA, with a maximum power rating of 10 W.

The multibank architecture of the PXI-2546 makes it ideal for test systems that require parallel operations such as RF stimulus-response testing. The module also provides excellent insertion loss, voltage standing-wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.

Note: The bandwidth specification of a switch module is not an absolute specification and is determined by vendor standards. Although you can route higher-frequency signals through this switch module, they encounter more degradation than those at lower frequencies. To determine the best switch module for your application, refer to the insertion loss, VSWR, and isolation specifications of the product for the bandwidth you need. For more information on choosing the right RF switch for your application, review the Guide to Selecting an RF Switch under the Resources tab of this page.



More National Instruments Corporation savings

Measure signals from a variety of sensors.
Develop automatic test systems with the NI PXI advantage.
Prototype and deploy embedded systems.
National Instruments Corporation 778572-46
Stock photo