30 minute quote  (888) 665-2765
Quote@GSAmart.com Mon - Fri 6am - 6pm PST

Digital Oscilloscopes at TestMart

Digital Oscilloscopes by Agilent Technologies

Agilent Technologies Digital Oscilloscope
  • 54754A Differential TDR module

  • 86108A 2 Channel Oscilloscope Receiver with Internal Clock Recovery and Precision Timebase

  • DSO5012A Oscilloscope, 2-channel, 100 MHz

  • DSO5014A Oscilloscope, 4-channel, 100 MHz

  • DSO5032A Oscilloscope, 2-channel, 300MHz

  • DSO5034A Oscilloscope, 4-channel, 300MHz

  • DSO5052A Oscilloscope, 2-channel, 500 MHz

  • DSO5054A Oscilloscope, 4-channel, 500 MHz

  • DSO6012A Oscilloscope, 2-channel, 100 MHz

  • DSO6014A Oscilloscope, 4-channel, 100 MHz

  • DSO6014L Oscilloscope, LXI, 4-channel, 100 MHz

  • DSO6032A Oscilloscope, 2-channel, 300 MHz

  • DSO6034A Oscilloscope, 4-channel, 300 MHz

  • DSO6052A Oscilloscope, 2-channel, 500 MHz

  • DSO6054A Oscilloscope, 4-channel, 500 MHz

  • DSO6054L Oscilloscope, LXI, 4-channel, 500 MHz

  • View all Agilent Technologies Digital Oscilloscopes

GSA Call 888-665-2765 for GSA

Digital Oscilloscopes by B+K Precision

B+K Precision Digital Oscilloscope
  • 2530B 25 MHz, 500 MSa/s Digital Storage Oscilloscope

  • View all B+K Precision Digital Oscilloscopes

GSA Call 888-665-2765 for GSA

Digital Oscilloscopes by Fluke

Fluke Digital Oscilloscope
  • 123-003 INDUSTRIAL SCOPEMETER 20MHZ

  • 123-003S INDUSTRIAL SCOPEMETER 20MHZ

  • 124 003

  • 124-003 INDUSTRIAL SCOPEMETER 40MHZ

  • 124-003S INDUSTRIAL SCOPEMETER 40MHZ

  • 192B-003 SCOPEMETER 60MHZ B/W USA (P/N 1634035)

  • 192B-003S SCOPEMETER 60MHZ B/W SCC USA (P/N 1634204)

  • 192C-003 EXTENDS WARRANTY FROM 3 TO 5 YEARS & INCLUDES ANNUAL NIST TRACEABLE CALIBRATION

  • 192C-003S EXTENDS WARRANTY FROM 3 TO 5 YEARS & INCLUDES ANNUAL NIST TRACEABLE CALIBRATION

  • 196B-003 SCOPEMETER 100MHZ B/W USA (P/N 1634372)

  • 196B-003S SCOPEMETER 100MHZ B/W SCC USA (P/N 1634542)

  • 196BM SCOPEMETER 100 MHZ B/W MEDICAL UNIVERSAL (P/N 2040270)

  • 196C-003 EXTENDS WARRANTY FROM 3 TO 5 YEARS & INCLUDES ANNUAL NIST TRACEABLE CALIBRATION

  • 196C-003S EXTENDS WARRANTY FROM 3 TO 5 YEARS & INCLUDES ANNUAL NIST TRACEABLE CALIBRATION

  • 196CM SCOPEMETER 100 MHZ COLOR MEDICAL UNIVERSAL (P/N 2040296)

  • 199B-003 SCOPEMETER 200MHZ B/W USA (P/N 1635050)

  • View all Fluke Digital Oscilloscopes

GSA Call 888-665-2765 for GSA

Digital Oscilloscopes by Teledyne LeCroy

Teledyne LeCroy Digital Oscilloscope
  • MSO-104MXS-B 1 GHz,5GS/s,4+18ch,16Mpts/Ch MSO with 10.4" Color Touch Screen Display.10GS/s,32Mpts Interleaved

  • MSO-44MXS-B 400 MHz, 5 GS/s, 4+18ch, 16 Mpts/Ch MSO with 10.4" Color Touch Screen Display.32Mpts Interleaved

  • MSO-64MXS-B 600 MHz,5GS/s,4+18ch,16Mpts/Ch MSO with 10.4" Color Touch Screen Display.10GS/s,32Mpts Interleaved

  • WAVEPRO-725Zi-A 2.5 GHz, 20 GS/s, 4ch, 20 Mpts/Ch DSO with 15.4" WXGA Color Display.

  • WAVERUNNER-604Zi 400 MHz, 10 GS/s, 4ch, 16 Mpts/Ch DSO with 12.1" WXGA Color Display.

  • WAVERUNNER-606Zi 600 MHz, 10 GS/s, 4ch, 16 Mpts/Ch DSO with 12.1" WXGA Color Display.

  • WAVERUNNER-610Zi 1 GHz, 10 GS/s, 4ch, 16 Mpts/Ch DSO with 12.1" WXGA Color Display.

  • WAVERUNNER-620Zi 2 GHz, 10 GS/s, 4ch, 16 Mpts/Ch DSO with 12.1" WXGA Color Display.

  • WAVERUNNER-625Zi 2.5 GHz, 20 GS/s, 4ch, 16 Mpts/Ch DSO with 12.1" WXGA Color Display.

  • WAVERUNNER-640Zi 4 GHz, 20 GS/s, 4ch, 16 Mpts/Ch DSO with 12.1" WXGA Color Display.

  • WAVESURFER-104MXS-B 1 GHz,5 GS/s,4ch,16 Mpts/Ch DSO with 10.4" Color Touch Screen Display.10GS/s,32 Mpts Interleaved

  • WAVESURFER-24MXS-B 200 MHz, 2.5 GS/s, 4ch, 16 Mpts/Ch DSO with 10.4" Color Touch Screen Display.32 Mpts Interleaved

  • WAVESURFER-42MXS-B 400 MHz, 5 GS/s, 2ch, 12.5 Mpts/Ch DSO with 10.4" Color Touch Screen Display. 25 Mpts Interleaved

  • WAVESURFER-44MXS-B 400 MHz, 5 GS/s, 4ch, 16 Mpts/Ch DSO with 10.4" Color Touch Screen Display. 32 Mpts Interleaved

  • WAVESURFER-62MXS-B 600 MHz,5 GS/s,2ch,16 Mpts/Ch DSO with 10.4" Color Touch Screen Display.10GS/s,32Mpts Interleaved

  • WAVESURFER-64MXS-B 600 MHz,5 GS/s,4ch,16 Mpts/Ch DSO with 10.4" Color Touch Screen Display.10GS/s,32Mpts Interleaved

  • View all Teledyne LeCroy Digital Oscilloscopes

GSA Call 888-665-2765 for GSA

Digital Oscilloscopes by Yokogawa

Yokogawa Digital Oscilloscope
  • 701230 DL750P ScopeCorder, 16Ch, 2.5 M/Ch, 50M total memory. Built-in wide format real-time printer.

  • 701250 High-speed, 10 MS/s, 12-bit, isolated inputs (2 channels)

  • 701251 High-speed, 1 MS/s, 16-bit, isolated inputs (2 channels)

  • 701255 High-speed, 10 MS/s, 12-bit non-isolated (2 channels)

  • 701260 High-voltage, 100 KS/s, 16-bit isolation with RMS (2 channels)

  • 701265 Temperature/high precision voltage module (2 channels)

  • 701270 Strain Module - NDIS connector (2 channels)

  • 701271 Strain Module - DSUB connector with shunt calibration (2

  • 701275 Acceleration/Voltage Module (with AAF) (2 channels)

  • 701280 Frequency Module (2 channels)

  • 701307 DL9040 Digital Oscilloscope. 4 channels. 500 MHz BW. 5 GS/s. 2.5 Mword/ch

  • 701308 DL9040L Digital Oscilloscope. 4 channels. 500 MHz BW. 5 GS/s. 6.25 Mword/ch

  • 701310 DL9140 Digital Oscilloscope. 4 channels. 1 GHz BW. 5 GS/s. 2.5 Mword/ch

  • 701311 DL9140L Digital Oscilloscope. 4 channels. 1 GHz BW. 5 GS/s. 6.25 Mword/ch

  • 701313 DL9240L Digital Oscilloscope. 4 channels. 1 .5GHz BW. 10 GS/s. 6.25 Mword/ch

  • 701320 DL9505L: Digital Oscilloscope 4ch 500 MHz + Logic 16bits, Max 5GS/s(2.5 GS/s/ch), 6.25 MW/ch

  • View all Yokogawa Digital Oscilloscopes

GSA Call 888-665-2765 for GSA

All Digital Oscilloscopes at TestMart

Overview:

An oscilloscope or scope is an electronic measuring instrument that creates a visible two-dimensional graph of one or more electrical potential differences. The horizontal axis of the display normally represents time, making the instrument useful for displaying periodic signals. The vertical axis usually shows voltage. The display is caused by a "spot" that periodically "sweeps" the screen from left to right.

Digital storage oscilloscope Oscilloscope software running in WindowsThe digital storage oscilloscope, or DSO for short, is now the preferred type for most industrial applications, although simple analogue CROs are still used by hobbyists. It replaces the unreliable storage method used in analogue storage scopes with digital memory, which can store data as long as required without degradation. It also allows complex processing of the signal by high-speed digital signal processing circuits. The vertical input, instead of driving the vertical amplifier, is digitised by an analog to digital converter to create a data set that is stored in the memory of a microprocessor. The data set is processed and then sent to the display, which in early DSOs was a cathode ray tube, but is now more likely to be an LCD flat panel. DSOs with colour LCD displays are common. The data set can be sent over a LAN or a WAN for processing or archiving. The scope's own signal analysis software can extract many useful time-domain features (e.g. rise time, pulse width, amplitude), frequency spectra, histograms and statistics, persistence maps, and a large number of parameters meaningful to engineers in specialized fields such as telecommunications, disk drive analysis and power electronics.

Example usage

The classic use of a scope is to diagnose a failing piece of electronic equipment. In a radio, for example, one looks at the schematic and tries to locate the connections between stages (e.g. electronic mixers, electronic oscillators, amplifiers).

Then one puts the scope's ground on the circuit's ground, and the probe of the scope on a connection between two of the stages in the middle of the train of stages.

When the expected signal is absent, one knows that some preceding stage of the electronics has failed. Since most failures occur because of a single faulty component, each measurement can prove that half of the stages of a complex piece of equipment either work, or probably did not cause the fault.

Once the failing stage is found, further probing of the defective stage can usually tell a skilled technician exactly which component is broken. Once the technician replaces the component, the unit can be restored to service, or at least the next fault can be isolated.

Another use is to check newly designed circuitry. Very often a newly-designed circuit will misbehave because of bad voltage levels, electrical noise or design errors. Digital electronics usually operates from a clock, so a dual-trace scope is needed to check digital circuits. "Storage scopes" are helpful for "capturing" rare electronic events that cause defective operation.

Another use is for software engineers who must program electronics. Often a scope is the only way to see if the software is running the electronics properly.