Product Description:
Agilent E4411B ESA-L 9kHz-1.5GHz Spectrum Analyzer
The Agilent E4411B spectrum analyzer is a wide band, very sensitive receiver. It works on the principle of "super-heterodyne receiver" to convert higher frequencies (normally ranging up to several 10s of GHz) to measurable quantities. The received frequency spectrum is slowly swept through a range of pre-selected frequencies, converting the selected frequency to a measurable DC level (usually logarithmic scale), and displaying the same on the CRT of the Agilent E4411B. The CRT displays received signal strength (y-axis) against frequency ( x-axis).
Some applications for Agilent E4411B Spectrum Analyzers include Site Monitoring: Verify that the frequency and signal strength of your transmitter is accurate. Interference: Before a system is installed you use a Agilent E4411B spectrum analyzer to verify that the frequencies (you plan to use) are not occupied or if the presence of a very strong signal will interfere with your new setup. Interference can be created by a number of different situations. Other tests that utilize the Agilent E4411B spectrum analyzer features include antenna isolation, co-channel interference, adjacent channel power, occupied bandwidth, intermodulation, microwave or satellite antenna alignment, and characterization of components.
Large monochrome VGA display
Auto background alignment
Amplitude correction
5-dB step attenuator
Built-in frequency counter
Snap-on battery optional
Rain-resistant front panel
Marker functions
Performance Characteristics of the E4411B
| Form Factor |
Benchtop |
| Input Impedance |
50 Ohm |
| Minimum Frequency |
9 kHz |
| Maximum Frequency |
1.5 GHz |
| Frequency Accuracy |
0.0000000002 % |
| Zero Span |
Yes |
| Minimum Span |
100 Hz |
| Maximum Span |
1.5 GHz |
| Minimum Sweep Time |
5 ms |
| Maximum Sweep Time |
2000 s |
| Minimum Resolution Bandwidth |
1 kHz |
| Maximum Resolution Bandwidth |
5 MHz |
| Resolution Bandwidth Steps |
1/3/10 |
| Minimum Video Bandwidth |
30 Hz |
| Maximum Video Bandwidth |
1 MHz |
| Video Bandwidth Steps |
1/3/10 |
| Minimum Single-Side-Band Noise |
-112 dBc/Hz |
| Maximum Single-Side-Band Noise |
-90 dBc/Hz |
| Maximum Safe AC Input |
30 dBm |
| Minimum Displayed Average Noise |
-117 dBm |
| Maximum Displayed Average Noise |
-113 dBm |
| Maximum Dynamic Range |
77 dB |
| Maximum Amplitude Uncertainty |
3.6666E-02 % |
| Trigger Source |
External,Internal |
| Trigger Modes |
Freerun,TTL |
| Demodulation |
AM |
| Connector type (main signal) |
Type-N(f) |
| Probe Power |
Yes |
| Noise Source Driver |
No |
Programmability/Connectivity of the E4411B
| User Interface |
Proprietary
|
| Test Pattern Storage |
50 Patterns
|
| Novram data storage |
Yes
|
| Data Storage Type |
FDD
|
| Programming Language |
SCPI
|
E4411B Compliance
| CE Compliance |
Not on file
|
| UL Compliance |
Not compliant
|
E4411B Power Requirements
| Input Power |
Universal (Auto Sense and Switch) |
E4411B Physical Dimensions
- Width: 373 mm(14.68 in)
- Height: 222 mm(8.74 in)
- Length: 409 mm(16.1 in)
- Weight: 12.6 kg(27.77 lb)
E4411B Standard Accessories
- E4401-90055 /Programmers Guide (w/conversion guide) /Qty:1
- E4401-90051 /Users Guide /Qty:1
- E4401-90053 /Reference Guide /Qty:1
- E4401-90054 /Calibration Guide /Qty:1
More Agilent savings