Product Description:
Anritsu 54147A Network Analyzer, 10 MHz to 20 GHz
The Anritsu 54147A network analyzer is an instrument which measures the complex transmission and reflection characteristics of two-port devices in the frequency domain. It does this by sampling the incident signal, separating the transmitted and reflected waves, and then performing ratios that are directly related to the reflection and transmission coefficients of the two-port. Frequency is swept to rapidly obtain amplitude and phase information over a band of frequencies of interest.
Anritsu 54147A network analyzers utilize synthesized-frequency sources to provide a known test stimulus that can sweep across a range of frequencies or power levels. Anritsu 54147A network analyzers also can perform ratioed measurements (including phase), which require multiple receivers. The Anritsu 54147A can provide a wealth of knowledge about a device under test (DUT), including its magnitude, phase, and group-delay response.
Fast,accurate measurement
Crystal-based source
Built-in automation
Built-in floppy disk
Rugged,reliable chassis
High Dynamic Range
High Resolution
N (f) Output Connector
Performance Characteristics of the 54147A
| Form Factor |
Benchtop |
| Type |
Scalar |
| Integral Signal Source |
Yes |
| Integral Test Set |
No |
| Source Minimum Frequency |
0.01 GHz |
| Source Maximum Frequency |
20 GHz |
| Source Frequency Resolution |
100 kHz |
| Source Frequency Accuracy |
0.00001 % |
| Output Impedance |
50 Ohm |
| No. of Receiver Channels |
2 ch |
| Minimum Dynamic Range |
71 dB |
| Maximum Dynamic Range |
71 dB |
Programmability/Connectivity of the 54147A
| User Interface |
Proprietary
|
| Ports to Peripheral Devices |
GPIB
|
| Test Pattern Storage |
13 Patterns
|
| Novram data storage |
Yes
|
| Data Storage Type |
FDD
|
54147A Compliance
| CE Compliance |
Compliant
|
| UL Compliance |
Not compliant
|
54147A Power Requirements
| Input Power |
Universal (Auto Sense and Switch) |
54147A Physical Dimensions
- Width: 426 mm(16.77 in)
- Height: 177 mm(6.96 in)
- Length: 476 mm(18.74 in)
- Weight: 18 kg(39.68 lb)
Options for 54147A
| Option |
US List Price |
| 54100A-16 / Option 16, +15 DC Supply for Millimeter Wave Source Modules (Available for models 20 GHz or lower). |
$780
|
| 54100A-25 / Option 25, Maintenance Manual (P/N: 10410-00166) |
No Charge
|
| 54100A-26 / Option 26, Extra Operation Manual and GPIB User's Guide (P/N: 10410-00141) |
$165
|
| 54100A-2A / Option 2A, 70 dB 20 GHz Step Attenuator (Models 54137A and 54147A) |
$2,850
|
| 54100A-5 / Option 5, Add Reference (R) Channel |
$1,005
|
| 54100A-6 / Option 6, Add External Leveling Capability |
$390
|
| 54100A-7 / Option 7, Internal Distance to Fault Software |
$3,895
|
| 54100A-8 / Option 8, Internal Relative Group Delay Software |
$5,190
|
| 54100A-98 / Z540/Guide 25 Calibration |
$705
|
| 54100A-99 / Premium Calibration |
$895
|
More Anritsu savings