Product specs for Agilent 6624A

Agilent 6624A

Product Description:

Agilent 6624A DC power supply, quad-output, 2 outputs at 7V/5A and 2 outputs at 20V/2A.GPIB

HPIB Calibration
Dual Range
Remote Sensing:1V

Performance Characteristics of the 6624A

Form Factor Benchtop
No. of Outputs 4 o/p
Range programming modes Fixed
Output 1 Max. power 40 Watts
Output 1/Range 1 Max. Current 5 A (0 V to 7 V)
Output 1/Range 2 Max. Current 2 A (0 V to 20 V)
Output 2 Max. power 40 Watts
Output 2/Range 1 Max. Current 5 A (0 V to 7 V)
Output 2/Range 2 Max. Current 2 A (0 V to 20 V)
Output 3 Max. Power 40 Watts
Output 3/Range 1 Max. Current 2 A (0 V to 20 V)
Output 3/Range 2 Max. Current 0.8 A (0 V to 50 V)
Output 4 Max. Power 40 Watts
Output 4/Range 1 Max. Current 2 A (0 V to 20 V)
Output 4/Range 2 Max. Current 0.8 A (0 V to 50 V)
Voltage Programming Accy Output1/Range1 2.7142E-03 %
Current Programming Accy Output1/Range1 0.1 %
Voltage Programming Accy Output1/Range2 0.00095 %
Current Programming Accy Output1/Range2 0.01 %
Voltage Programming Accy Output2/Range1 2.7142E-03 %
Current Programming Accy Output2/Range1 0.1 %
Voltage Programming Accy Output2/Range2 0.00095 %
Current Programming Accy Output2/Range2 0.025 %
Voltage Programming Accy Output3/Range1 0.0025 %
Current Programming Accy Output3/Range1 0.01 %
Voltage Programming Accy Output3/Range2 0.001 %
Current Programming Accy Output3/Range2 0.025 %
Voltage Programming Accy Output4/Range1 0.0025 %
Current Programming Accy Output4/Range1 0.01 %
Voltage Programming Accy Output4/Range2 0.001 %
Current Programming Accy Output4/Range2 0.025 %
Voltage Readback Accy Output1/Range1 2.8571E-03 %
Current Readback Accy Output1/Range1 0.002 %
Voltage Readback Accy Output1/Range2 0.001 %
Current Readback Accy Output1/Range2 0.005 %
Voltage Readback Accy Output2/Range1 2.8571E-03 %
Current Readback Accy Output2/Range1 0.002 %
Voltage Readback Accy Output2/Range2 0.001 %
Current Readback Accy Output2/Range2 0.005 %
Voltage Readback Accy Output3/Range1 0.0025 %
Current Readback Accy Output3/Range1 0.002 %
Current Readback Accy Output3/Range2 0.005 %
Current Readback Accy Output4/Range1 0.002 %
Current Readback Accy Output4/Range2 0.005 %
Voltage Ripple and Noise 500 uV
Current Ripple and Noise 1 mA
Load Regulation, Voltage 2 mV
Load Regulation, Current 1 mA
Load Cross Regulation, Voltage 2.5 mV
Load Cross Regulation, Current 1 mA
Line Regulation, Voltage 1 mV
Line Regulation, Current 1 mA
Transient Response Time 75 us
Programming Response Time 6 ms
Programming Resolution (% of full scale) 0.03 %
Remote Sensing Measurement Yes
Multiple Unit Combinations Parallel,Series
Overvoltage Protection Yes
Overcurrent Protection Yes
Over-temperature Protection Yes
Local Lockout Yes
Calibration security Jumper
Self test Yes

Programmability/Connectivity of the 6624A

User Interface Proprietary
Ports to Peripheral Devices HPIB

6624A Compliance

CE Compliance Compliant
UL Compliance Compliant

6624A Power Requirements

Input Power 550W Max, 720VA Max.

6624A Physical Dimensions

  • Width: 425 mm(16.73 in)
  • Height: 132 mm(5.19 in)
  • Length: 498 mm(19.6 in)
  • Weight: 17.4 kg(38.36 lb)

6624A Standard Accessories

  • 5957-6377 /Operation Manual /Qty:1

More Agilent savings

Agilent N9340B15% off low cost handheld spectrum analyzer
Agilent DSO7054AFree 7 day trial on new Agilent 7000 series oscilloscopes
Agilent N9010AFree 7 day trial on new Agilent N9010A spectrum analyzer
Agilent N9340BFree 7 day trial on new Agilent N9340B handheld spectrum analyzer
Agilent 5000Agilent 5000 Series Portable Oscilloscopes - Capture Events Other Oscilloscopes Miss
Save up to 30% on combined orders
Free Agilent RF/Microwave Test Accessories catalog
Debugging Embedded Mixed-Signal Designs
View Movie Infinium 9000 demo
Open Promo PDF Agilent GSA Promotions

Used, refurbished at

Agilent 6624A