Product Description:
Keithley Instruments 2016 Total Harmonic Distortion 6-1/2 Digit DMM w/9V Source Power Output
Performance Characteristics of the 2016
| Form Factor |
Benchtop |
| Number of Digits (Max) |
6.5 digits |
| DC Volts Minimum Range |
100 mV |
| DC Volts Maximum Range |
1000 V |
| DC Volts No. of Ranges |
5 QTY |
| DC Volts Range Steps |
1/10/100 |
| DC Volts Minimum Resolution |
0.1 uV |
| DC Volts Maximum Resolution |
1 mV |
| DC Volts Maximum Reading Rate |
5 pt/sec |
| AC Volts Minimum Range |
100 mV |
| AC Volts Maximum Range |
750 V |
| AC Volts No. of Ranges |
5 QTY |
| AC Volts Range Steps |
1/10/100 |
| AC Volts Minimum Frequency |
3 Hz |
| AC Volts Maximum Frequency |
300 kHz |
| AC Volts Minimum Resolution |
0.1 uV |
| AC Volts Maximum Resolution |
1 mV |
| AC Volts Maximum Reading Rate |
2 pt/sec |
| AC Volts Basic 1 Year Accuracy |
4 % |
| True Rms (?) |
Yes |
| Normal Mode Rejection Ratio |
60 dB |
| Common mode Rejection Ratio |
140 dB |
| DC Current Minimum Range |
10 mA |
| DC Current Maximum Range |
3 A |
| DC Current No. of Ranges |
5 QTY |
| DC Current Range Steps |
1/10/100 |
| DC Current Minimum Resolution |
10 nA |
| DC Current Maximum Resolution |
10 uA |
| DC Current Maximum Reading Rate |
5 pt/sec |
| DC Current Basic 1 yr accuracy |
0.12 % |
| AC Current Minimum Range |
1 A |
| AC Current Maximum Range |
3 A |
| AC Current No. of Ranges |
2 QTY |
| AC Current Range Steps |
1/10/100 |
| AC Current Minimum Resolution |
1 uA |
| AC Current Maximum Resolution |
10 uA |
| AC Current Maximum Reading Rate |
2 pt/sec |
| AC Current Basic 1 Year Accuracy |
0.0000000015 % |
| Resistance 2 wire/4 wire |
2 Wire,4 Wire |
| Resistance Minimum Range |
100 Ohm |
| Resistance Maximum Range |
100 MOhm |
| Resistance No. of Ranges |
7 QTY |
| Resistance Range Steps |
1/10/100 |
| Resistance Minimum Resolution |
100 uOhm |
| Resistance Maximum Resolution |
100 Ohm |
| Resistance Maximum Reading Rate |
5 pt/sec |
| Resistance Basic 1 yr accuracy |
0.15 % |
| Minimum Frequency |
20 Hz |
| Maximum Frequency |
20 kHz |
| Frequency Accuracy |
0.01 % |
Programmability/Connectivity of the 2016
| User Interface |
Proprietary
|
| Ports to Peripheral Devices |
GPIB,RS232C
|
| Novram data storage |
Yes
|
| Programming Language |
SCPI
|
2016 Compliance
| CE Compliance |
Compliant
|
| UL Compliance |
Compliant
|
2016 Power Requirements
| Input Power |
Universal (Auto Sense and Switch)
|
2016 Physical Dimensions
- Width: 213 mm(8.38 in)
- Height: 89 mm(3.5 in)
- Length: 370 mm(14.56 in)
- Weight: 4.2 kg(9.25 lb)
2016 Standard Accessories
- 1 /Model 1751 Safety Test Leads /Qty:1
- 2 /User Manual /Qty:1
- 3 /Service Manual /Qty:1