Instruments For Industry TCCX2200
Stock photo

Instruments For Industry TCCX2200 Amplifier,TWT: 2200Watts,220MHz (Stand alone)

Specifications for TCCX 2200 :

Power and frequency

2200 Watts saturated power

1800 Watts minimum linear power (at 1 dB compression)

Instantaneous frequency range: 0.01 to 220 MHz

Performance characteristics

Small signal gain: 65 dB

Gain control range: > 40 dB

Bandpass flatness: ± 2.0 dB (at 1 dB compression)

Maximum harmonics: -20 dBc

Spurious signals: < -60 dBc

Input VSWR: 2.0 : 1

Input Impedance: 50 ohms

Output Impedance: 50 ohms

RF rise and fall time: 100 ns

Front panel display and controls

Gain control dial with infinite resolution adjustment

Meters with selection knob to monitor tube voltages and currents

Overload, filament on, auto-limit, no air flow, wait, and panel open indicators

Lighted push-buttons for on, off, operate, overload reset, and standby functions

Toggle switches for external leveling control

Leveling control (ALC)

Can take in an external leveling signal ranging from 1 to 5 Volts through a BNC connection

Amplifier monitoring and protection

Primary and secondary overloads

Unconditionally stable against load mismatches

Can tolerate up to 100% of reflected RF power; i.e., will operate into any impedance from a short circuit to an open circuit

Auto-limit tube protection circuitry that limits the drive through the final stages to a safe level

Will automatically go into a wait mode when air circulation or tube filament voltages are lost

Exterior panel interlocks, that when open, will put the amplifier into standby mode and discharge all capacitors

Cooling

Completely air cooled with IFI's unique Quiet Cool® design

RF signal connectors

Input: Type BNC located on front panel; 8 dBm maximum input

Output: Type N located on front panel

Electrical power requirements

208 or 380 Volts AC (customer must specify at time of order; other options available)

50/60 Hz line frequency

Three phase

21 kVA power consumption

Dimensions and weight

Height: 72 in. (183 cm)

Width: 33 in. (84 cm)

Depth: 36 in. (91 cm)

Weight: 650 lbs. (295 kg)

Environmental requirements

Operating temperature: 32° to 113° F (0° to 45° C)

Relative humidity (without condensation): 95%

Maximum altitude: 10,000 ft. (3,048 m)

--------------------------------------------------------------------------------

Available Options

--------------------------------------------------------------------------------

RF power indication

Forward and reverse digital power indication via directional coupler

Internal IEEE-488 interface

Allows for remote computer control of the amplifier (contact IFI for custom control configurations)

RF sample port

Allows for measurement of the amplified signal at -50 dB through a BNC connection (-56 dB if RF power indication is also installed)

One GHz driver

Replaces the 0.01 to 220 MHz solid state driver amplifier with a 0.01 to 1000 MHz version.

Door interlock

A BNC connection that will automatically shut off the amplifier when triggered (e.g., door open signal)

Pulse power

Can also operate in a pulse mode with up to six times the linear power rating


Superior durability
Completely air cooled
Instantaneous frequency range
Gain control range of greater than 40 dB
Built-in solid state driver amplifier and preamplifier
Unconditionally stable against load mismatches
Auto-limit tube protection circuitry
Expandable

 